H.323 Trunk <strong>Admin</strong>istration 2 H.323 Trunks<br />

Field<br />

Far-end Node Name:<br />

Far-end Listen Port:<br />

LRQ Required?<br />

Calls Share IP<br />

Signaling Connection?<br />

Bypass if IP Threshold<br />

Exceeded?<br />

>Go to page 2<br />

Conditions/Comments<br />

This is the node name <strong>for</strong> the far-end C-LAN IP<br />

Interface used <strong>for</strong> trunks assigned to this signaling<br />

group. The node name must be administered on the<br />

Node Names <strong>for</strong>m on this switch.<br />

This field can be left blank if the signaling group is<br />

associated with an unspecified destination.<br />

The same number as entered in the Near-end Listen<br />

Port field is re<strong>com</strong>mended; this number must match the<br />

number entered in the Near-end Listen Port field on the<br />

signaling group <strong>for</strong>m <strong>for</strong> the far-end switch.<br />

This field can be left blank if the signaling group is<br />

associated with an unspecified destination.<br />

Leave the default (n) if the far-end switch is a<br />

DEFINITY <strong>ECS</strong>. Set to y only if the far-end switch is a<br />

non-DEFINITY switch and requires a location request<br />

(to obtain a signaling address) in its signaling protocol.<br />

Always enter y <strong>for</strong> inter-DEFINITY connections. If the<br />

local and/or remote switch is a non-DEFINITY switch,<br />

leave the default (n).<br />

Set to y to automatically remove from service trunks<br />

assigned to this signaling group when IP transport<br />

per<strong>for</strong>mance falls below limits administered on the<br />

Maintenance-Related System Parameters (sys par<br />

maint) screen.<br />

2 of 2<br />

add signaling-group next Page 2 of 5<br />

If this signaling group will be used <strong>for</strong> DCS, enter NCA TSC in<strong>for</strong>mation here. See<br />

Chapter 3, Configuration 4, <strong>for</strong> instructions.<br />

> Submit the screen<br />

End<br />

ADMINISTERED NCA TSC ASSIGNMENT<br />

Service/Feature:<br />

As-needed Inactivity Time-out (min):<br />

TSC Local Mach.<br />

Index Ext. Enabled Established Dest. Digits Appl. ID<br />

1: n<br />

2: n<br />

3: n<br />

4: n<br />

5: n<br />

6: n<br />

7: n<br />

8: n<br />

44<br />

<strong>Admin</strong>istration <strong>for</strong> <strong>Network</strong> <strong>Connectivity</strong><br />

CID: 77730 555-233-504 — Issue 1 — April 2000

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!