Components of fuel supply system, servicing<br />

Página 41 de 42<br />

20-36<br />

Test sequence<br />

Note:<br />

With this check the fuel supply line<br />

connections from the fuel delivery<br />

unit to the point at which the<br />

pressure gauge VAG 1318 is<br />

connected will be checked for leaks<br />

at the same time.<br />

- Close pressure gauge shut-off tap<br />

(lever across flow direction -<br />

position B-).<br />

- Operate remote control at short<br />

intervals, until a pressure of<br />

approx. 3 bar has built up.<br />

- If pressure builds up too high,<br />

lower excess pressure by<br />

carefully opening shut-off tap.<br />

WARNING!<br />

Danger of spray when opening the<br />

shut-off-tap; hold container in<br />

front of the free connection on the<br />

pressure gauge.<br />

- Observe pressure drop on gauge.<br />

Over a duration of 10 minutes<br />

pressure must not drop below a<br />

2.5 bar decrease.<br />

If the pressure drops further:<br />