14.02.2016 Views

Bentley Volkswagen.Golf.Jetta.R32.Official.Factory.Repair.Manual.1999-2005

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Climatronic On Board Diagnostic (OBD) through m.y. 2001<br />

Página 41 de 52<br />

01-46<br />

Display<br />

group<br />

number<br />

Display<br />

field<br />

Designation<br />

Code 4: Not displayed.<br />

Code: 5 -N25- switched off<br />

for 4 seconds (no<br />

malfunction). Code 5 is<br />

only displayed for 5<br />

seconds. If continuous,<br />

check speed signal.<br />

Code 6: -N25- switched off<br />

with ECON button (no<br />

malfunction).<br />

Code 7: -N25- switched off<br />

because A/C system is<br />

switched off via button for<br />

fresh air blower speed (no<br />

malfunction).<br />

Code 8: -N25- switched off<br />

because ambient<br />

temperature is below 3 C<br />

(37 F) (to prevent icing, no<br />

malfunction). Check<br />

temperature sensors -G17-<br />

and -G89-.<br />

Continued on next page<br />