Pressures, checking on vehicles<br />

Página 19 de 33<br />

absolute<br />

B - Control current for A/C<br />

Compressor Regulator Valve<br />

N280<br />

C - Permissible tolerance range.<br />

Note:<br />

- Under unfavorable conditions<br />

(very high ambient temperatures,<br />

high humidity), pressure on highpressure<br />

side may increase to<br />

max. 29 bar.<br />

- Control current - B - is displayed<br />

in measured value block.<br />

- High pressure is displayed in<br />

measured value block<br />

<strong>Repair</strong> Manual, , <strong>Repair</strong> Group<br />

87,<br />

.<br />

- Low pressure settles as a<br />

function of control current for A/C<br />

Compressor Regulator Valve<br />

N280 within compressor output<br />

range in tolerance range.<br />

- Under unfavorable conditions<br />

(very high ambient temperatures,<br />

high humidity), compressor output<br />

may not always be sufficient to<br />

attain the specified value.<br />

- The specified operating current<br />

for the regulating valve must be<br />

greater than 0.3 A in order to<br />

ensure reliable valve actuation.<br />

- In the setting "maximum cooling<br />

output" control current is regulated<br />

to approx. 0.8 A (displayed in<br />

measured value block)<br />

<strong>Repair</strong> Manual, Heating & Air<br />

Conditioning, <strong>Repair</strong> Group 87 ,<br />