Pressures, checking on vehicles<br />

Página 11 de 33<br />

attained.<br />

- If quantity of refrigerant extracted<br />

is substantially greater than<br />

specified capacity:<br />

- Re-charge refrigerant circuit.<br />

- Repeat test.<br />

Note:<br />

- Overfilling with refrigerant oil can<br />

occur if, for example, the<br />

compressor has been replaced<br />

without adjusting the quantity of<br />

refrigerant oil.<br />

Expansion valve and<br />

receiver (with internally<br />

regulated compressor),<br />

checking<br />

Note:<br />

- Connect service station 00-6,<br />

Service station, connecting .<br />

- Observe test conditions 00-7,<br />

Pressures, checking on vehicles .<br />

- Set engine speed to 2000 RPM.<br />

- Observe pressure gauge set.<br />

Note:<br />

- Switching pressures and<br />

arrangement of refrigerant circuit<br />

switches are vehicle-specific.<br />

Pressures must be measured at<br />

service connections; component<br />

locations of these connections are<br />

vehicle-specific<br />

<strong>Repair</strong> Manual, Heating & Air<br />

Conditioning, <strong>Repair</strong> Group 87 ,<br />

Specified values:<br />

http://ebahn.bentleypublishers.com/vw/servlet/Display?action=Next&type=repair&id=...<br />

13/2/<strong>2005</strong>