General information on refrigerant circuit<br />

Página 15 de 21<br />

water (ice-up safeguard).<br />

Coolant FC (Fan Control) Control Module J293<br />

Note:<br />

- There are various construction styles.<br />

This control module switches on and off the A/C clutch and<br />

therefore the A/C compressor. It switches the coolant fans<br />

and (in vehicles with High Pressure Sensor G65 or A/C<br />

Pressure/temperature Sensor G395 ) calculates the<br />

pressure in the refrigerant circuit.<br />

A/C Evaporator Temperature Switch E33<br />

Function:<br />

A/C Evaporator Temperature Switch E33 determines the<br />

temperature between the evaporator cooling ribs. It<br />

prevents the possibility of ice build-up between evaporator<br />

cooling ribs by interrupting the current supply to A/C clutch<br />

of A/C compressor when temperature at the cooling ribs<br />

sinks to the freezing point for air moisture.<br />

Insertion depth of the sensor tube is marked or listed in the<br />

repair manual<br />

<strong>Repair</strong> Manual, Heating & Air Conditioning, <strong>Repair</strong><br />

Group 87 ,<br />

http://ebahn.bentleypublishers.com/vw/servlet/Display?action=Next&type=repair&id=...<br />

13/2/<strong>2005</strong>