Measured value (data) blocks<br />

Página 55 de 86<br />

01-236<br />

Display group 99 - Oxygen Sensor (O2S) control - Oxygen Sensor (O2S) control<br />

operating condition<br />

Engine running at idle<br />

Control module in function "04-Basic setting", Oxygen Sensor (O2S) control off<br />

Control module in function "08-Read measured value block", Oxygen Sensor<br />

(O2S) control on<br />

System in basic<br />

setting 99<br />

Indicated on display<br />

Read measured<br />

value block 99<br />

xxxx<br />

rpm<br />

xxx.x<br />

C<br />

x.xx Text<br />

1 2 3 4 Display zones Specification Evaluation<br />

Oxygen Sensor (O2S)<br />

control operating<br />

condition:<br />

---<br />

in function "04"<br />

in function "08"<br />

Oxygen Sensor (O2S) control,<br />

current value<br />

-Reg. ON<br />

-Reg. ON<br />

0,96...1.04 ---<br />

Coolant temperature 80.0...110.0<br />

C<br />

Page 01-<br />

195<br />

Engine speed (idle speed) 640...720 rpm Page 01-<br />

188<br />

Notes on display zone 4:<br />

For a defined fault finding the Oxygen Sensor (O2S) control is switched off when<br />

selecting display group 99 under "04-Basic setting" or switched on under "08-Read<br />

measured value block". When the function "04-Basic setting" is exited the Oxygen<br />

Sensor (O2S) control is automatically active again.<br />

It is possible to switch between the function "04-Basic setting" and the function "08-<br />

Read measured value block" by pressing the buttons 4 and 8 on VAG 1551/1552.<br />