Secondary air system<br />

Página 26 de 35<br />

26-45<br />

Calibrating the KLI 9210 tester<br />

Determine the vehicle leak threshold:<br />

Up to and including M.Y. 1999 leak<br />

threshold = 0.040 in.<br />

From M.Y. 2000 leak threshold = 0.020 in.<br />

- Attach test hose to appropriate pre-set port<br />

(black arrows).<br />

- Turn control valve from "Hold" to "Test".<br />

- Set flow meter flag (white arrow) at indicated<br />

value on flow meter.<br />

- Turn control valve to "Hold"; remove test hose.<br />

Testing the fuel cap<br />

- Remove fuel cap.<br />

- Connect fuel cap receiver (arrow) to hose.<br />

- Screw fuel cap tightly to cap receiver.<br />

- Turn control valve to "Test" pressurizing cap.<br />

- Turn valve to "Hold".<br />

- Watch pressure gauge for drop in pressure from<br />

14 inches H 2<br />

O.<br />

http://ebahn.bentleypublishers.com/vw/servlet/Display?action=Goto&type=repair&id=...<br />