<strong>XTP</strong> Power Page<br />
The <strong>XTP</strong> Power page (see figure 64) provides a location to enable <strong>and</strong> disable PoX for<br />
all <strong>XTP</strong> inputs <strong>and</strong> outputs. Access the <strong>XTP</strong> Power page by clicking the <strong>XTP</strong> Power link<br />
on the left of theon the Set <strong>and</strong> View Ties, Input Adjustments, Output Adjustments, EDID<br />
Configuration, or Presets page. Select (check) <strong>and</strong> deselect (uncheck) the Enable Power<br />
box.<br />
NOTES:<br />
• PoX is supplied by the <strong>XTP</strong> <strong>CrossPoint</strong> 48 V power supply.<br />
• <strong>XTP</strong> <strong>CrossPoint</strong> <strong>1600</strong>:<br />
• Can power up to 28 total (input <strong>and</strong> output) endpoints at up to 364 watts.<br />
• Is available with optional 48 V power supply redundancy.<br />
• The <strong>XTP</strong> <strong>CrossPoint</strong> <strong>3200</strong>:<br />
• Can power up to 24 total (input <strong>and</strong> output) endpoints at up to 312 watts.<br />
• No 48 V power supply redundancy is available.<br />
Figure 64. <strong>XTP</strong> Power Page<br />
<strong>XTP</strong> <strong>CrossPoint</strong> <strong>1600</strong> <strong>and</strong> <strong>3200</strong> Switchers • HTML Operation 132