Extron XTP CrossPoint 1600 and 3200 ... - Extron Electronics
Extron XTP CrossPoint 1600 and 3200 ... - Extron Electronics
Extron XTP CrossPoint 1600 and 3200 ... - Extron Electronics
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
SIS Comm<strong>and</strong> <strong>and</strong> Response Table for Input-Board-Specific Comm<strong>and</strong>s (continued)<br />
Comm<strong>and</strong> Function<br />
SIS Comm<strong>and</strong><br />
(Host to Unit)<br />
Response<br />
(Unit to Host)<br />
Additional description<br />
Inputs on <strong>XTP</strong> CP 4i HDMI <strong>and</strong> <strong>XTP</strong> CP 4i DVI Pro Boards (continued)<br />
HDCP status<br />
View input HDCP status E I X^HDCP } X1$]<br />
View HDCP status of all inputs E I*HDCP } X1$ 1 X1$ 2 X1$ 3 ... X1$ n ]<br />
Inputs on <strong>XTP</strong> CP 4i [<strong>XTP</strong>] Boards<br />
Captive screw <strong>and</strong> Ethernet serial port insertion enables<br />
Enable an input captive screw serial<br />
port insertion<br />
E I X^*0LRPT } LrptIX^*0 ] Enable the captive screw serial port<br />
insert on input X^. This disables the<br />
Ethernet RS-232 insert.<br />
Enable an input Ethernet serial port<br />
insertion<br />
E I X^*1LRPT } LrptIX^*1 ] Enable the Ethernet serial port insert<br />
on input X^. This disables the captive<br />
screw serial port insert.<br />
Set all RS-232 input insertions E I* X1% *LRPT } LrptI00*X1%]<br />
View input insertion E I X^LRPT } X1%]<br />
View all input insertions E ILRPT } X1% 1 X1% 2 X1% 3 ... X1% n ] One X1% for each available (installed)<br />
input, starting at input 1. Inputs that are<br />
not on an <strong>XTP</strong> CP 4i [<strong>XTP</strong>] board report<br />
as 0.<br />
Ethernet serial port insert parameters<br />
Set serial port parameters EX1^*X1& , X1* , X1( , X2) CP }<br />
CpnX1^•Ccp X1& , X1* , X1( , X2)]<br />
Read serial port parameters EX1^CP } X1&,X1*,X1(,X2)]<br />
Configure current port timeout E 0* X2! TC } Pti0*X2!]<br />
Read current port timeout E 0TC } X2!]<br />
Configure global IP port timeout E 1* X2! TC } Pti1*X2!]<br />
Read global IP port timeout E 1TC } X2!]<br />
Set UART start point EX2@ MD } PmdX2@] Sets the initial (lowest) port number for<br />
the range of numbers assigned to the<br />
serial port <strong>and</strong> UARTs.<br />
Read UART start point E MD } X2@]<br />
NOTE: X^ = Input number (for other than tie) 01 – 16 or 32<br />
X1$ = HDCP status (for inputs) 0 = No source device connected<br />
1 = Source connected is HDCP-compliant<br />
2 = Source connected is not HDCP-compliant<br />
X1% = Captive screw or UART 0 = Captive screw RS-232 insert (default) 1 = Ethernet RS-232 insert (UART)<br />
X1^ = Port number 03 — 34 = UARTs (inputs) 1 — 32<br />
X1& = Baud rate 9600 (default), 19200, 38400, 115200<br />
X1* = Parity odd, even, none, mark, space (only the first letter is required)<br />
X1( = Data bits 7, 8 (default)<br />
X2) = Stop bits 1 (default), 2<br />
X2! = Port timeout (10-sec. increments) 1 (= 10 seconds) - 65000 (default is 30 = 300 seconds = 5 minutes)<br />
X2@ = UART starting point<br />
The starting point (X2@) is the rear panel RS-232/RS-422 port.<br />
The next position (X2@ +1 ) is not used.<br />
For the <strong>XTP</strong> <strong>CrossPoint</strong> <strong>1600</strong>, X2@ +2 through X2@ +18 are <strong>XTP</strong> inputs.<br />
For the <strong>XTP</strong> <strong>CrossPoint</strong> <strong>3200</strong>, X2@ +2 through X2@ +34 are <strong>XTP</strong> inputs.<br />
Default values: 1999 = Rear panel remote RS-232/RS-422 port<br />
2000 is unused<br />
2001 through 2016 (<strong>XTP</strong> <strong>CrossPoint</strong> <strong>1600</strong>) = Input 1 through 16<br />
2001 through 2032 (<strong>XTP</strong> <strong>CrossPoint</strong> <strong>3200</strong>) = Input 1 through 32<br />
<strong>XTP</strong> <strong>CrossPoint</strong> <strong>1600</strong> <strong>and</strong> <strong>3200</strong> Switchers • Programming Guide 84