Removing and Installing the User Flange<br />

7.4 Internal User Connectors<br />

The internal user connectors, OP3/4, EOAPWR, and ESTOP, can be accessed with the<br />

Outer Link cover removed - see Figure 7-4. The SOLND connector is located on the<br />

opposite of the bulkhead area - see Figure 7-5.<br />

OP3/4<br />

EOAPWR<br />

J3-BRK<br />

NOT USED<br />

Note: On early <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> s600<br />

robots, the J3-BRK and<br />

ESTOP connectors are in<br />

opposite locations from those<br />

shown in the photo. Verify the<br />

function by inspecting the label<br />

on the socket.<br />

Figure 7-4. Internal User Connectors - OP3/4, EOAPWR, ESTOP<br />

WARNING: When the Outer link cover is removed, you<br />

see the label shown above. Do not remove the J3-ENC or<br />

J4-ENC encoder cable connectors from their sockets. If<br />

they are removed, the calibration data will be lost and the<br />

robot must be run through a factory recalibration process,<br />

which requires special software and tools.<br />

SOLND Connector<br />

Figure 7-5. SOLND Connector<br />

<s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>PLC600</s<strong>tr</strong>ong>/PLC800 Robot User’s <s<strong>tr</strong>ong>Guide</s<strong>tr</strong>ong>, Rev B 105