PLC Software Overview<br />

Error Registers<br />

When an error occurs, the Error Registers described in Table 6-11 are written to by the PLC<br />

Server. The maximum length of each s<strong>tr</strong>ing value is 82 characters.<br />

Table 6-11. Error Register Definitions<br />

RSLogix 500 RSLogix 5000 Description<br />

ST245:0 <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong>_Error.0 Current error message<br />

ST245:1 <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong>_Error.1 Date and time error occurred<br />

ST245:2 <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong>_Error.2 Cartesian location of the robot<br />

ST245:3 <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong>_Error.3 Joint-coordinate location of<br />

the robot<br />

ST245:4 <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong>_Error.4 Cartesian destination of the<br />

robot<br />

ST245:5 <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong>_Error.5 Command words received by<br />

the PLC Server<br />

All the error registers are cleared by the PLC Server when a Fault Reset <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mand is<br />

processed.<br />

The current error register (ST245:0 or <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong>_Error.0) contains the current PLC Server<br />

message s<strong>tr</strong>ing (see “PLC Server Messages” on page 149).<br />

The date and time of the error is provided in ST35:1 or <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong>_Error.1.<br />

A Cartesian description of the location of the robot at the time of the error is provided in<br />

ST245:2 or <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong>_Error.2 (the format is described below).<br />

The joint positions of the robot at the time of the error is provided in ST245:3 or<br />

<s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong>_Error.3 (the format is described below).<br />

A Cartesian description of the destination location of the robot at the time of the error is<br />

provided in ST245:4 or <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong>_Error.4 (the format is described below).<br />

The values of all the Command Registers at the time of the error are provided in ST245:5<br />

or <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong>_Error.5 (the format is described below).<br />

The s<strong>tr</strong>ing formats are as follows:<br />

• For ST245:1<br />

dd-Mmm-yyyy hh:mm:ss<br />

where “dd-Mmm-yyyy” represents the date and “hh:mm:ss” represents the time<br />

(in 24-hour format).<br />

• For ST245:2 and ST245:4<br />

X=xx.xx Y=xx.xx Z=xx.xx y=xx.xx p=xx.xx r=xx.xx<br />

where “xx.xx” represents a positive or negative real value with one or more<br />

integer digits and two fractional digits.<br />

<s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>PLC600</s<strong>tr</strong>ong>/PLC800 Robot User’s <s<strong>tr</strong>ong>Guide</s<strong>tr</strong>ong>, Rev B 95