Wiring the System<br />

Table 4-12. DIO Output Specifications (XDIO connector)<br />

Operating voltage range<br />

Operational current range, per channel<br />

Vdrop across output in “on” condition<br />

0 to 24 VDC<br />

I out ≤ 100 mA, short-circuit<br />

Protected<br />

V drop ≤ 2.7 V at 100 mA<br />

V drop ≤ 2.0 V at 10 mA<br />

Output off leakage current I out ≤ 600 µA<br />

Turn on response time (hardware)<br />

Software scan rate/response time<br />

Turn off response time (hardware)<br />

Software scan rate/response time<br />

3 µsec maximum<br />

16 ms scan cycle/ 32 ms max.<br />

response time<br />

200 µsec maximum<br />

16 ms scan cycle/ 32 ms max.<br />

response time<br />

Figure 4-16 shows two examples of different connections to the digital outputs on the<br />

XDIO connector. The examples are negative <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mon and positive <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mon using the<br />

internal 24V and ground connections.<br />

Example 1: outputs 0001 to 0004 are shown with positive <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mon.<br />

Example 2: outputs 0005 to 0008 are shown with negative <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mon.<br />

68 <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>PLC600</s<strong>tr</strong>ong>/PLC800 Robot User’s <s<strong>tr</strong>ong>Guide</s<strong>tr</strong>ong>, Rev B