Optional Robot Equipment Installation<br />

Internal User Connector Output Specifications<br />

The output specifications in Table 7-4 apply to the EOAPWR, OP3/4, and SOLND<br />

internal user connectors.<br />

Table 7-4. Internal User Connector Output Circuit Specifications<br />

Parameter<br />

Value<br />

Power supply voltage range See Table 4-4 on page 49.<br />

Operational current range, per I out ≤ 700 mA<br />

channel<br />

Total Current Limitation, all channels<br />

on. a<br />

I total ≤ 1.0 A @ 50°C ambient<br />

I total ≤ 1.5A @ 25°C ambient<br />

On state resistance (I out = 0.5A) R on ≤ 0.32Ω @ 85°C<br />

Output leakage current I out ≤ 25 µA<br />

Turn on response time<br />

125 µsec. max., 80 µsec typical<br />

(hardware only)<br />

Turn off response time<br />

60 µsec. max., 28 µsec typical<br />

(hardware only)<br />

Output voltage at inductive load (+V - 65) ≤ V demag ≤ (+V - 45)<br />

turnoff (I out = 0.5A, Load = 1 mH)<br />

DC short circuit current limit 0.7A ≤ I LIM ≤ 2.5 A<br />

Peak short circuit current<br />

I ovpk ≤ 4A<br />

a Note: Total current is the sum of the output current used by output<br />

signals 3001-3004 (SOLND and OP3/4) and any user current drawn<br />

from EOAPWR.<br />

7.5 Mounting Locations for External Equipment<br />

Three locations are provided for mounting user external equipment on the robot arm. The<br />

first location is on the J1 Harness Support (top side of the inner link), a second is on the<br />

top side of the outer link, and a third is on the bottom side of the outer link. Each location<br />

has a set of four tapped holes. See Figure 9-4 on page 130 for the dimensions.<br />

NOTE: The cover on the outer link must be removed for maintenance<br />

(lubrication), so keep this in mind when mounting any external<br />

equipment to the outer link cover.<br />