Connecting 24 VDC Power to Robot<br />

Procedure for Creating 24 VDC Cable<br />

1. Locate the connector and pins from Table 4-5 on page 49.<br />

2. Use 14-16 AWG wire to create the 24 VDC cable. Select the wire length to safely<br />

reach from the user-supplied 24 VDC power supply to the robot base.<br />

NOTE: You also must create a separate 24 VDC cable for the PLC Server.<br />

That cable uses a different style of connector. See Section 4.8 on page 55<br />

for details.<br />

3. Crimp the pins onto the wires using the crimping tool re<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mended in Table 4-5<br />

on page 49.<br />

4. Insert the pins into the connector. Confirm that the 24V and ground wires are in<br />

the correct terminals in the plug.<br />

5. Prepare the opposite end of the cable for connection to your user-supplied 24<br />

VDC power supply.<br />

Installing 24 VDC Robot Cable<br />

1. Connect one end of the 24 VDC cable to your user-supplied 24 VDC power<br />

supply. Do not turn on the 24 VDC power until ins<strong>tr</strong>ucted to do so in Chapter 5.<br />

2. Plug the mating connector end of the 24 VDC cable into the 24 VDC connector on<br />

the interface panel on the back of the robot.<br />

<s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong><br />

i600/i800 Robot<br />

– +<br />

Shield<br />

User-Supplied Shielded<br />

Power Cable<br />

+<br />

–<br />

User-Supplied<br />

Power Supply<br />

24VDC<br />

Optional User<br />

Equipment<br />

Figure 4-4. User-Supplied 24 VDC Cable<br />

NOTE: In order to maintain <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>pliance with EN standards, DC power<br />

must be delivered over a shielded cable, with the shield connected to the<br />

return conductors at both ends of the cable.<br />

<s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>PLC600</s<strong>tr</strong>ong>/PLC800 Robot User’s <s<strong>tr</strong>ong>Guide</s<strong>tr</strong>ong>, Rev B 51