Wiring the System<br />
Connecting Equipment to the System<br />
The connection of the customer-supplied safety and power con<strong>tr</strong>ol equipment to the<br />
system is done through the XUSR and XFP connectors on the PLC Server. The XUSR<br />
connector (25-pin) and XFP (15-pin) connector are both female D-sub connectors located<br />
on the front panel of the PLC Server. Refer to Table 4-9 for the XUSR pin-out explanations.<br />
Refer to Table 4-10 on page 61 for the XFP pin-out explanations. See Figure 4-13 on page<br />
62 for the XUSR wiring diagram.<br />
Table 4-9. Contacts Provided by the XUSR Connector<br />
Pin<br />
Pairs<br />
Description<br />
Comments<br />
Shorted if<br />
NOT Used<br />
Voltage-Free Contacts Provided by Customer<br />
1, 14<br />
User E-Stop CH 1 (mushroom PB,<br />
safety gates, etc.).<br />
N/C contacts<br />
Yes<br />
2,15<br />
User E-Stop CH 2 (same as pins 1<br />
and 14).<br />
N/C contacts<br />
Yes<br />
3,16<br />
Line E-Stop (used for other robot or<br />
assembly line E-Stop<br />
interconnection. Does not affect<br />
E-Stop indication (pins 7, 20.))<br />
N/C contacts<br />
Yes<br />
4,17<br />
Line E-Stop (Same as pins 3 and 16.<br />
See above <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>ment.)<br />
N/C contacts<br />
Yes<br />
5,18<br />
Muted safety gate CH 1 (causes<br />
E-stop in AUTOMATIC mode only).<br />
N/C contacts<br />
Yes<br />
6,19<br />
Muted Safety Gate CH 2 (same as<br />
pins 5 and 18).<br />
N/C contacts<br />
Yes<br />
Voltage-Free Contacts provided by <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong><br />
7,20<br />
8,21<br />
9,22<br />
10,23<br />
11,12,<br />
13,24,25<br />
E-Stop indication CH 1.<br />
E-stop indication CH 2 (same as pins<br />
7 and 20.<br />
MANUAL/AUTO indication CH 1<br />
MANUAL/AUTO indication CH 2<br />
No connection<br />
Contacts are closed when<br />
Front Panel, MCP, and<br />
customer E-Stops are not<br />
<strong>tr</strong>ipped<br />
Contacts are closed when<br />
Front Panel, MCP, and<br />
customer E-stops are not<br />
<strong>tr</strong>ipped<br />
Contacts are closed in<br />
AUTOMATIC mode<br />
Contacts are closed in<br />
AUTOMATIC mode<br />
60 <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>PLC600</s<strong>tr</strong>ong>/PLC800 Robot User’s <s<strong>tr</strong>ong>Guide</s<strong>tr</strong>ong>, Rev B