Wiring the System<br />

Connecting Equipment to the System<br />

The connection of the customer-supplied safety and power con<strong>tr</strong>ol equipment to the<br />

system is done through the XUSR and XFP connectors on the PLC Server. The XUSR<br />

connector (25-pin) and XFP (15-pin) connector are both female D-sub connectors located<br />

on the front panel of the PLC Server. Refer to Table 4-9 for the XUSR pin-out explanations.<br />

Refer to Table 4-10 on page 61 for the XFP pin-out explanations. See Figure 4-13 on page<br />

62 for the XUSR wiring diagram.<br />

Table 4-9. Contacts Provided by the XUSR Connector<br />

Pin<br />

Pairs<br />

Description<br />

Comments<br />

Shorted if<br />

NOT Used<br />

Voltage-Free Contacts Provided by Customer<br />

1, 14<br />

User E-Stop CH 1 (mushroom PB,<br />

safety gates, etc.).<br />

N/C contacts<br />

Yes<br />

2,15<br />

User E-Stop CH 2 (same as pins 1<br />

and 14).<br />

N/C contacts<br />

Yes<br />

3,16<br />

Line E-Stop (used for other robot or<br />

assembly line E-Stop<br />

interconnection. Does not affect<br />

E-Stop indication (pins 7, 20.))<br />

N/C contacts<br />

Yes<br />

4,17<br />

Line E-Stop (Same as pins 3 and 16.<br />

See above <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>ment.)<br />

N/C contacts<br />

Yes<br />

5,18<br />

Muted safety gate CH 1 (causes<br />

E-stop in AUTOMATIC mode only).<br />

N/C contacts<br />

Yes<br />

6,19<br />

Muted Safety Gate CH 2 (same as<br />

pins 5 and 18).<br />

N/C contacts<br />

Yes<br />

Voltage-Free Contacts provided by <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong><br />

7,20<br />

8,21<br />

9,22<br />

10,23<br />

11,12,<br />

13,24,25<br />

E-Stop indication CH 1.<br />

E-stop indication CH 2 (same as pins<br />

7 and 20.<br />

MANUAL/AUTO indication CH 1<br />

MANUAL/AUTO indication CH 2<br />

No connection<br />

Contacts are closed when<br />

Front Panel, MCP, and<br />

customer E-Stops are not<br />

<strong>tr</strong>ipped<br />

Contacts are closed when<br />

Front Panel, MCP, and<br />

customer E-stops are not<br />

<strong>tr</strong>ipped<br />

Contacts are closed in<br />

AUTOMATIC mode<br />

Contacts are closed in<br />

AUTOMATIC mode<br />

60 <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>PLC600</s<strong>tr</strong>ong>/PLC800 Robot User’s <s<strong>tr</strong>ong>Guide</s<strong>tr</strong>ong>, Rev B