Connecting Customer-Supplied Safety and Power Con<strong>tr</strong>ol Equipment<br />

<s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> Front Panel Schematic<br />

ESTOPSRC<br />

XFP<br />

15PDSUBM<br />

5VD<br />

24VS<br />

1<br />

2<br />

MANUALSRC1<br />

3<br />

MANUALSRC2<br />

4<br />

HPLT5V<br />

5<br />

6<br />

SYSPWRLT 7<br />

NC 8<br />

16<br />

9<br />

10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

ESTOPFP1<br />

ESTOPFP2<br />

MANUALRLY1<br />

MANUALRLY2<br />

HIPWRLT<br />

HIPWRREQ<br />

17<br />

D<br />

"System Power LED"<br />

"MANUAL/AUTO"<br />

"HIGH POWER ON/OFF"<br />

"EMERGENCY STOP"<br />

5VD<br />

HPLT5V<br />

SYSPWRLT<br />

MANUALSRC2<br />

MANUALSRC1<br />

24VS<br />

ESTOPSRC<br />

2PIN_MINI<br />

D<br />

SWL1<br />

D<br />

SW1<br />

SW2<br />

MANUALRLY2<br />

MANUALRLY1<br />

HIPWRLT<br />

HIPWRREQ<br />

ESTOPFP2<br />

ESTOPFP1<br />

Figure 4-14. Optional Front Panel Schematic<br />

Emergency Stop Circuits<br />

The PLC Server provides connections for Emergency Stop (E-Stop) circuits on the XUSR<br />

and XFP connectors. This gives the PLC Server system the ability to duplicate E-Stop<br />

functionality from a remote location using voltage-free contacts. See Figure 4-13 on page<br />

62.<br />

The XUSR connector provides external two-channel E-Stop input on pins 1 to 14 and 2 to<br />

15. The XFP connector provides two-channel E-Stop input on pins 1 to 9 and 2 to 10.<br />

NOTE: These pins must be shorted if not used. Both channels must open<br />

independently if used. Although an Emergency Stop will occur, the PLC<br />

Server will malfunction if one channel is jumpered closed and the other<br />

channel is opened. It will also malfunction if the channels are shorted<br />