Installing Robot Solenoid Kit<br />
7.6 Installing Robot Solenoid Kit<br />
In<strong>tr</strong>oduction<br />
This procedure describes how to mount the 24V solenoid option kit on an <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong><br />
PLC robot. The solenoid kit is available as <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> P/N 02853-000.<br />
The robot has been prewired to ac<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>modate a bank of two 24 VDC solenoid valves.<br />
Power for the internal mounting is accessible via a connector mounted inside the outer<br />
link cover (see Figure 7-7 on page 110). The signals actuating the valves are directly<br />
switchable from the PLC. Refer to Chapter 6 for register information.<br />
Each driver is designed to handle 24 VDC solenoids at a nominal 75 mA per valve.<br />
The solenoid valve assembly consists of two independent valves (Valve #1 and Valve #2)<br />
on a <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mon manifold. The manifold supplies air at the user’s line pressure (28 psi<br />
minimum to 114 psi maximum). Each valve has two output ports, A and B. The output<br />
ports are arranged so that when Port A is pressurized, Port B is not pressurized.<br />
Conversely, when Port B is pressurized, Port A is not. In the <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> PLC robots, the<br />
air lines from Port A on each valve are plugged at the factory (at the solenoid assembly).<br />
The Solenoid Kit for the <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> PLC robot is available through <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong>. Contact your<br />
<s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> Sales Representative for current price and availability.<br />
Tools Required<br />
Procedure<br />
• Assorted Allen drivers<br />
•Tie-wraps<br />
• Pair of diagonal wire cutters<br />
• Solenoid Valve upgrade Kit (<s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> P/N 02853-000)<br />
1. Turn off all power to the robot.<br />
2. Remove two screws on the <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> PLC 600 (three screws on <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> PLC 800) on<br />
each side of the outer link cover. Remove two screws on top and remove the<br />
cover.<br />
3. Connect the Internal Solenoid Valve Cable assembly to the Solenoid Manifold<br />
assembly, by plugging the SOL 1 connector into Valve 1 and SOL 2 into Valve 2.<br />
<s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>PLC600</s<strong>tr</strong>ong>/PLC800 Robot User’s <s<strong>tr</strong>ong>Guide</s<strong>tr</strong>ong>, Rev B 109