Connecting Customer-Supplied Digital I/O Equipment<br />

NOTE: The input current specifications are provided for reference; voltage<br />

sources are typically used to drive the inputs.<br />

In the following figure, example 1 shows inputs (1001 to 1004) with a negative <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mon,<br />

example 2 shows inputs (1005 to 1008) with a positive <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mon, and example 3 shows<br />

inputs (1009 to 1012) with an independent power supply (no <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mon).<br />

NOTE: These are examples. Either method can be used on any channel.<br />

<s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong>-Supplied Equipment<br />

(equivalent circuit)<br />

+ 1<br />

Signal 1001<br />

– 2<br />

Customer-Supplied Equipment<br />

(Typical Examples)<br />

Example 1<br />

XDIO Connector on PLC Server - Inputs<br />

Signal 1002<br />

Signal 1003<br />

Signal 1004<br />

Signal 1005<br />

Signal 1006<br />

Signal 1007<br />

Signal 1008<br />

Signal 1009<br />

Signal 1010<br />

+<br />

–<br />

+<br />

–<br />

+<br />

–<br />

+<br />

–<br />

+<br />

–<br />

+<br />

–<br />

+<br />

–<br />

+<br />

–<br />

+<br />

–<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

17<br />

18<br />

19<br />

20<br />

+ –<br />

+ –<br />

+<br />

–<br />

+<br />

–<br />

Customer power<br />

supply<br />

Example 2<br />

Customer power<br />

supply<br />

Example 3<br />

Sourcing<br />

Signal 1011<br />

Signal 1012<br />

+<br />

–<br />

+<br />

–<br />

21<br />

22<br />

23<br />

24<br />

+ –<br />

+ –<br />

Sinking<br />

Figure 4-15. Digital Input Wiring Examples (XDIO Connector)<br />

NOTE: Power from pins 41-44 and 47-50 can be substituted for the<br />

customer power supply. See Figure 4-16 on page 69 and Table 4-12 on<br />

page 68 for additional information.<br />

Output Signals<br />

The XDIO connector handles output signals 0001 to 0008. Refer to Table 4-12 for output<br />

specifications. The locations of the signals on the connector are shown in Table 4-13 on<br />

page 70. The XDIO connector provides separate positive and negative connections for<br />

each channel (no internal <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mon connections). This allows the choice of wiring for<br />

current-sourcing or current-sinking modes.<br />

<s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>PLC600</s<strong>tr</strong>ong>/PLC800 Robot User’s <s<strong>tr</strong>ong>Guide</s<strong>tr</strong>ong>, Rev B 67