Connecting Customer-Supplied Digital I/O Equipment<br />
NOTE: The input current specifications are provided for reference; voltage<br />
sources are typically used to drive the inputs.<br />
In the following figure, example 1 shows inputs (1001 to 1004) with a negative <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mon,<br />
example 2 shows inputs (1005 to 1008) with a positive <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mon, and example 3 shows<br />
inputs (1009 to 1012) with an independent power supply (no <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mon).<br />
NOTE: These are examples. Either method can be used on any channel.<br />
<s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong>-Supplied Equipment<br />
(equivalent circuit)<br />
+ 1<br />
Signal 1001<br />
– 2<br />
Customer-Supplied Equipment<br />
(Typical Examples)<br />
Example 1<br />
XDIO Connector on PLC Server - Inputs<br />
Signal 1002<br />
Signal 1003<br />
Signal 1004<br />
Signal 1005<br />
Signal 1006<br />
Signal 1007<br />
Signal 1008<br />
Signal 1009<br />
Signal 1010<br />
+<br />
–<br />
+<br />
–<br />
+<br />
–<br />
+<br />
–<br />
+<br />
–<br />
+<br />
–<br />
+<br />
–<br />
+<br />
–<br />
+<br />
–<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
14<br />
15<br />
16<br />
17<br />
18<br />
19<br />
20<br />
+ –<br />
+ –<br />
+<br />
–<br />
+<br />
–<br />
Customer power<br />
supply<br />
Example 2<br />
Customer power<br />
supply<br />
Example 3<br />
Sourcing<br />
Signal 1011<br />
Signal 1012<br />
+<br />
–<br />
+<br />
–<br />
21<br />
22<br />
23<br />
24<br />
+ –<br />
+ –<br />
Sinking<br />
Figure 4-15. Digital Input Wiring Examples (XDIO Connector)<br />
NOTE: Power from pins 41-44 and 47-50 can be substituted for the<br />
customer power supply. See Figure 4-16 on page 69 and Table 4-12 on<br />
page 68 for additional information.<br />
Output Signals<br />
The XDIO connector handles output signals 0001 to 0008. Refer to Table 4-12 for output<br />
specifications. The locations of the signals on the connector are shown in Table 4-13 on<br />
page 70. The XDIO connector provides separate positive and negative connections for<br />
each channel (no internal <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mon connections). This allows the choice of wiring for<br />
current-sourcing or current-sinking modes.<br />
<s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>PLC600</s<strong>tr</strong>ong>/PLC800 Robot User’s <s<strong>tr</strong>ong>Guide</s<strong>tr</strong>ong>, Rev B 67