Check Robot for Oil Around Harmonic Drive<br />

8.6 Replacing the SmartAmp AIB Chassis<br />

This procedure provides details on how to replace the SmartAmp AIB chassis on a <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong><br />

PLC robot.<br />

CAUTION: Follow appropriate ESD procedures during the<br />

removal/replacement phases.<br />

Removing the SmartAmp AIB Chassis<br />

1. Switch off the PLC Server.<br />

2. Switch off the 24 VDC input supply to the chassis.<br />

3. Switch off the 200/240VAC input supply to the chassis.<br />

4. Disconnect the 24 VDC supply cable from the chassis +24 VDC input connector.<br />

See Figure 4-2 on page 44 for locations of connectors.<br />

5. Disconnect the 200/240VAC supply cable from the chassis AC Input connector.<br />

6. Disconnect the XSLV cable from the chassis XSLV connector.<br />

7. Disconnect the 1394 cable from the chassis SmartServo connector.<br />

8. Disconnect any other cables, which may be connected to the chassis, such as XIO,<br />

RS-232, or any others.<br />

9. Using a 5 mm Allen key, carefully unscrew the chassis securing screw. See Figure<br />

8-2. Note that the screw does not need to be <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>pletely removed in order to<br />

remove the chassis, as this screw is captured on the chassis heat sink.<br />

Securing Screw on<br />

SmartAmp AIB<br />

Figure 8-2. Securing Screw on SmartAmp AIB Chassis<br />

10. While holding the chassis heat sink, carefully and slowly lower the chassis down<br />

(see Figure 8-3 on page 120), so that enough access is available to remove the<br />

internal cables. The chassis can be laid flat or placed to the right side of the robot<br />

for better access.<br />

<s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>PLC600</s<strong>tr</strong>ong>/PLC800 Robot User’s <s<strong>tr</strong>ong>Guide</s<strong>tr</strong>ong>, Rev B 119

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!