PLC Server Messages<br />

*Invalid pallet number* Pallet n (-3012)<br />

The pallet number specified in N240:8 or <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong>_Pallet_Number is either less than one<br />

or larger than the maximum location number permitted.<br />

*Invalid speed parameter* Speed n (-3013)<br />

The motion speed specified in N240:4 or <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong>_Speed is either less than zero for a<br />

regular robot motion, or outside the allowable range (-127 to 127) for jogging the<br />

robot.<br />

*MSG ins<strong>tr</strong>uctions not allowed* (-3018)<br />

After sending a message to the PLC, the response was a reply message.<br />

*Only one axis bit can be set while jogging* (-3008)<br />

More than one robot axis or coordinate direction is selected in N240:2 or<br />

<s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong>_Jog_Mode, which is permitted only in FREE mode.<br />

*Pallet locations are linear* (-3021)<br />

The three robot locations that were specified to define a pallet lie on a line. The third<br />

location must be off the line that passes through the first two locations.<br />

*PLC Server start-up error* Code n (-3019)<br />

One of the following errors was detected during startup of the PLC Server software,<br />

as indicated by the value of “n”:<br />

1 The required con<strong>tr</strong>oller license is not installed.<br />

2 The V+ system is older than version 16.1D5.<br />

System initialized and ready to run (Vx.xx) (3001)<br />

The PLC Server has <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>pleted its initialization and is ready for operation.<br />

*Undefined location* Location n (-3015)<br />

An attempt has been made to use a location that has not been defined.<br />

*Undefined pallet* Pallet n (-3016)<br />

An attempt has been made to use a pallet that has not been defined.<br />

*Unknown processor type* ID n (-3017)<br />

The PLC Server software does not recognize the processor in the <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> PLC Server.<br />