Wiring the System<br />

Figure 4-13 shows an E-Stop diagram for the CAT-3 version of the <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> PLC Server.<br />

E-Stop, High Power On/Off, and MANUAL/AUTO Con<strong>tr</strong>ols for<br />

CAT-3 Version of the PLC Server<br />

Front Panel<br />

ES1<br />

Front Panel<br />

Front<br />

Panel<br />

System<br />

Power<br />

LED<br />

ES2<br />

Manual/Auto<br />

Enable<br />

XFP-3<br />

XFP-11<br />

MM1<br />

Manual/Auto Keyswitch<br />

- Manual = Open (|)<br />

- Manual => ( 100%<br />

XFP-5<br />

XFP-13<br />

5 V<br />

5 V<br />

Logic cyclic<br />

check state<br />

machines<br />

Channel 1<br />

Channel 2<br />

24 V<br />

XFP-7<br />

Grn<br />

XFP-15<br />

XFP-4<br />

XFP-12<br />

XFP-6<br />

6V, 1.2 W<br />

bulb<br />

XFP-14<br />

MM2<br />

24 V<br />

E-Stop<br />

Enable<br />

I limit = 1.4 A<br />

MCP-4 Enable<br />

Switch<br />

(not used for<br />

<s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> PLC)<br />

High<br />

Power<br />

On / Off<br />

24 V<br />

Front Panel<br />

ES1<br />

MM1<br />

MCP<br />

Internal Connections<br />

Channel 1<br />

ESTOPSRC<br />

XFP-1<br />

XFP-9<br />

ES2<br />

ESTOPSRC<br />

MM2<br />

XFP-2<br />

XFP-10<br />

ES1<br />

MM1<br />

Channel 2<br />

F<br />

ES2<br />

MM2<br />

M<br />

XUSER-2<br />

XUSER-1<br />

XUSER-14<br />

XUSER-15<br />

XUSER-7<br />

XUSER-8<br />

XUSER-21<br />

XUSER-20<br />

XUSER-4<br />

XUSER-3<br />

XUSER-16<br />

XUSER-17<br />

XUSER-9<br />

XUSER-10<br />

XUSER-23<br />

XUSER-22<br />

XUSER-6<br />

XUSER-5<br />

XUSER-18<br />

XUSER-19<br />

User Supplied Connections<br />

User E-Stop and<br />

Gate Interlock<br />

(Jumper closed when<br />

not used, MUST open<br />

both channels<br />

independently if used.)<br />

User E-Stop Indication<br />

Line E-Stop<br />

(External User<br />

E-Stop system)<br />

User Manual / Auto Indication<br />

(Manual = Open)<br />

Muted Safety Gate<br />

- Active in auto mode<br />

only<br />

(Jumper closed when<br />

not used)<br />

Burned out<br />

bulb notify<br />

(prevents High<br />

Power enable)<br />

HP Light<br />

Enable)<br />

-<br />

+<br />

0.24V<br />

4.7<br />

High<br />

Power<br />

request<br />

XSYS-5<br />

E-Stop<br />

Reset<br />

XSYS-2<br />

XSYS-3<br />

E-Stop<br />

Manual 1<br />

XSYS-6<br />

E-Stop<br />

Manual 2<br />

XSYS-7<br />

E-Stop<br />

Auto 1<br />

E-Stop<br />

Auto 2<br />

ESTOPSRC<br />

XSYS-9<br />

XSYS-1<br />

XSYS signals go to PDU or MAI-2 when required (No User Connection)<br />

Figure 4-13. CAT-3 E-Stop Circuit on XUSR and XFP Connectors<br />

62 <s<strong>tr</strong>ong>Adept</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>Cobra</s<strong>tr</strong>ong> <s<strong>tr</strong>ong>PLC600</s<strong>tr</strong>ong>/PLC800 Robot User’s <s<strong>tr</strong>ong>Guide</s<strong>tr</strong>ong>, Rev B