Chapter<br />

8<br />

Terminal Operation<br />

8.1 Power on <strong>RAID</strong> Enclosure<br />

Hardware installation should be completed before powering on your<br />

<strong>RAID</strong> enclosure. Drives must be configured and the controller<br />

properly initialized before host computer can access the storage<br />

capacity. The configuration and administration utility resides in<br />

controller's firmware.<br />

Open the initial terminal screen: use arrow keys to move cursor bar<br />

through menu items, then press [ENTER] to choose the terminal<br />

emulation mode, and [ESC] to return to the previous menu/screen.<br />

8.2 Caching Parameters<br />

Optimization Modes<br />

Mass storage applications fall into two major categories: database<br />

applications and video/imaging applications. The controller<br />

supports two embedded optimization modes: Optimization for<br />

Random I/O and Optimization for Sequential I/O.<br />

Limitations: There are limitations on the optimization modes. First,<br />

one optimization mode must be applied to all logical units in a <strong>RAID</strong><br />

system. Second, once the optimization mode is selected and data<br />

written in logical units, the only way to change the optimization<br />

Terminal Operation 8-1