12.2 Preparing <strong>Controller</strong>s<br />

12.2.1 Requirements:<br />

To set up the redundant function, you must perform some basic steps.<br />

These steps will be discussed in the following section.<br />

Cabling Requirements:<br />

Communications Channels:<br />

- <strong>Controller</strong> Communications (Cache Synchronizing) Paths:<br />

<strong>Controller</strong> RCC cable<br />

3101 & 3102 series IFT-9013 and IFT-9016 + SCSI CH0<br />

Sentinel<strong>RAID</strong> A SCSI cable (CH 0)<br />

Eon<strong>RAID</strong> 2000-4 Two SCSI cables (CH 6&7)<br />

Eon<strong>RAID</strong> 2000-6 Two RCC cables (IFT-9536)<br />

Fibre cables: Communications over<br />

two of the dedicated I/O channels or<br />

using all drive loops to distribute<br />

comm. traffic<br />

- Using one or two I/O channels for controller communications<br />

(as listed above) is necessary especially when write-back<br />

caching is preferred. If controllers are running in write-back<br />

mode, a battery module is recommended for each controller.<br />

- Use the default channel (CH 0) for the Sentinel<strong>RAID</strong>s. For the<br />

Eon<strong>RAID</strong> users, if the communications over Fibre is preferred,<br />

the RCC cables (IFT-9536) should be connected to provide the<br />

connection between controller detect signals.<br />

Out-of-band Configuration<br />

- RS-232C cable (for Terminal Interface Operation) connection.<br />

Configuring two independent controllers into the redundant<br />

mode requires the IFT-9535.<br />

- Ethernet connection: If management through Ethernet is<br />

preferred, connect the Ethernet interface from both controllers<br />

to ports on a hub. The IP address assigned to one controller<br />

will be inherited by another should controller failover occur.<br />

Host and Drive Connection<br />

- All channels must be connected between controllers<br />

Redundant <strong>Controller</strong> 12-11