NOTE:<br />

11. Type "Pathname" for value name, and set data type to<br />

REG_EXPAND_SZ, then click on "OK" button.<br />

12. Type "%SystemRoot%\System32\<strong>RAID</strong>SNMP.DLL" for string,<br />

then click on "OK" button.<br />

13. Close REGEDT32, then the SNMP Agent is ready for <strong>Infortrend</strong><br />

<strong>RAID</strong> Manager.<br />

14. Restart the SNMP service or restart your system.<br />

• The names and values in the NT registry are case sensitive.<br />

13.11.4 How to Configure the SNMP Trap<br />

1. In order to let the SNMP trap working properly, the<br />

"<strong>RAID</strong>COMM.INI" file must be copied in the system root directory<br />

(\WINNT).<br />

2. The Descriptions of Contents of the "<strong>RAID</strong>COMM.INI"<br />

Examples:<br />

[TRAP]<br />

PERIOD=30<br />

SEVERITY=0<br />

Comments:<br />

A There should be a section of "trap". The value of "PERIOD"<br />

specify the minimum interval of sequential traps. It is in<br />

seconds. For example, as above, it is 30 seconds.<br />

B The value of "Severity " is a filter to mask the traps that is less<br />

than its value. The value of "Severity" is considered when the<br />

value of "PERIOD" is positive.<br />

C The SNMP agent communicates to the <strong>RAID</strong> controller<br />

through in-band SCSI by default. To change the<br />

communication route to RS-232C, please refer to the next<br />

paragraph.<br />

D While the Text <strong>RAID</strong> Manager is running and communicates<br />

to the <strong>RAID</strong> controller through the in-band SCSI, the SNMP<br />

traps will not be able to send. It is a must to exit the Text<br />

<strong>RAID</strong> Manager in order to send the SNMP trap properly.<br />

E While the Text <strong>RAID</strong> Manager is running locally, the remote<br />

SNMP connection (GUI via SNMP) cannot be established. It is<br />

a must to exit the local Text <strong>RAID</strong> Manager in order to<br />

perform remote administration via SNMP.<br />

3. The SNMP agent communicates to the <strong>RAID</strong> controller through inband<br />

SCSI by default. To change the communication route to<br />

RS-232C, please add:<br />

In-band Text <strong>RAID</strong> Manager and SNMP Agent Installation 13-29