10-22<br />

NOTE:<br />

Clone + Replace:<br />

<strong>Controller</strong> will enable all drives' S.M.A.R.T. function. If a drive<br />

predicts problem, controller will report in the form of event log.<br />

<strong>Controller</strong> will then clone the drive with predictable failure to a<br />

standby spare drive and take “the predict failure drive” off-line as<br />

soon as the cloning process is completed.<br />

• If your system is using drives of different brand under the control of the same<br />

controller, as long as they are ANSI-SCSI Informational Exception Control (IEC)<br />

document X3T10/94-190 compatible, it should not be an issue working with the<br />

controller.<br />

Enabling the S.M.A.R.T. Feature<br />

Follow the procedure listed below to enable S.M.A.R.T. on all drives.<br />

1. First, enable the “Periodic Drive Check Time” function. In \View<br />

and Edit Configuration Parameters\Drive-side SCSI<br />

Parameters\Periodic Drive Check Time, choose a time interval.<br />

2. In \View and Edit Configuration Parameters\Drive-side SCSI<br />

Parameters\Drive Predictable Failure Mode , choose one<br />

from “Detect Only,” “Detect, Perpetual Clone” and “Detect,<br />

Clone+Replace.”<br />