6-12<br />

Adding a Global Spare Drive<br />

Press ENT for two seconds to enter the<br />

Main Menu. Press ▼ or ▲ to select<br />

"View and Edit SCSI Drives," then press<br />

ENT.<br />

SCSI drive information will be<br />

displayed on the LCD. Press ▼ or ▲ to<br />

select a SCSI drive that has not been<br />

assigned to any logical drive yet, then<br />

press ENT.<br />

Press ▼ or ▲ to select “Add Global<br />

Spare Drive,” then press ENT.<br />

Press ENT again for two seconds to add<br />

the spare drive. The message “Add<br />

Global Spare Drive Successful” will be<br />

displayed on the LCD.<br />

Rebuild Settings<br />

Press ENT for two seconds to enter the<br />

Main Menu. Press ▼ or ▲ to select<br />

"View and Edit Config Parms," then<br />

press ENT.<br />

Press ▼ or ▲ to select “Disk Array<br />

Parameters,” then press ENT.<br />

Press ▼ or ▲ to select “Rebuild Priority<br />

Low,” then press ENT. “Low” refers to<br />

the temporary setting.<br />

Press ENT again and the abbreviation<br />

mark “..” will change to question mark<br />

“?”. Press ▼ or ▲ to select priority Low,<br />

Normal, Improved, or High on the LCD.<br />

Press ENT to confirm and the question<br />

mark “?” will turn into “..”.<br />

View and Edit<br />

SCSI Drives ↕<br />

C=2 I=4 1010MB<br />

NEW DRV SEAGATE<br />

Add Global Spare<br />

Drive ..<br />

Add Global Spare<br />

Drive Successful<br />

View and Edit<br />

Config Parms ↕<br />

Disk Array<br />

Parameters..<br />

Rebuild Priority<br />

Low ..<br />

Rebuild Priority<br />

Low ?<br />

Rebuild Priority<br />

High ..<br />

<strong>Infortrend</strong>