default setting is "Disabled". The message "Redundant <strong>Controller</strong> -<br />

Disabled" will be displayed on the screen. Press [ENTER] to<br />

proceed.)<br />

The message "Enable Redundant <strong>Controller</strong> in Autoconfigure Mode"<br />

will appear. Use the arrow keys to scroll through the available<br />

options ("Primary," "Secondary," or "Autoconfigure"). Press [ENTER]<br />

on "Primary."<br />

• Power off controller 1, then power on controller 2. Set controller 2<br />

to "Secondary" as described in the above steps.<br />

• Power off controller 2.<br />

• Power on both controllers, drives, and host computer for the<br />

settings to take effect.<br />

• During normal operation, the controllers continuously monitor<br />

each other. Each controller is always ready to take over for the<br />

other controller in an unlikely event of a controller failure.<br />

• The Primary and Secondary controllers synchronize each other’s<br />

configurations at frequent intervals through the established<br />

communications path(s). Write-back cache will be disabled if no<br />

sync. cache path exists.<br />

• Select "View and Edit SCSI Channels" from the Main Menu, the<br />

communications path will be displayed as "RCCOM (Redundant<br />

<strong>Controller</strong> Communications)."<br />

Redundant <strong>Controller</strong> 12-25