• head flying height<br />

• data throughput performance<br />

• spin-up time<br />

• re-allocated sector count<br />

• seek error rate<br />

• seek time performance<br />

• spin try recount<br />

• drive calibration retry count<br />

SCSI drives with reliability prediction capability only communicate a<br />

reliability condition as either good or failing. In a SCSI environment,<br />

the failure decision occurs at the disk drive, and the host notifies the<br />

user for action. The SCSI specification provides a sense bit to be<br />

flagged if the disk drive determines that a reliability issue exists. The<br />

system then alerts the user/system administrator.<br />

B. <strong>Infortrend</strong>'s Implementations to S.M.A.R.T.<br />

<strong>Infortrend</strong> is using ANSI-SCSI Informational Exception Control (IEC)<br />

document X3T10/94-190 standard.<br />

There are four manual selections related to S.M.A.R.T. function in<br />

firmware:<br />

Disable:<br />

S.M.A.R.T. function not activated<br />

Detect Only:<br />

S.M.A.R.T. function enabled, controller will send command to enable<br />

all the drives' S.M.A.R.T. function, if a drive predicts problem,<br />

controller will report the predicted problem in the form of an event<br />

log.<br />

Perpetual Clone:<br />

If the S.M.A.R.T. function is enabled, the controller will send<br />

command to enable all drives' S.M.A.R.T. function. If a drive predicts<br />

problem, controller will report in the form of an event log. <strong>Controller</strong><br />

will clone the drive if there is a Dedicated/Global spare drive<br />

available. “The predict failure drive” will not be taken off-line, and<br />

the clone drive will still behave as a standby drive.<br />

If “the predict failure drive” fails, the clone drive will take over<br />

immediately. Under the circumstance that “the predict failure drive“<br />

is still working and another drive in the same logical drive should<br />

fail, the clone drive will perform as a standby spare drive and start to<br />

rebuild the failed drive immediately. This is to prevent a fatal drive<br />

error if yet another drive should fail.<br />

Advanced Configurations 10-21