8-14<br />

Move cursor bar to the SCSI drive that is not assigned to a logical<br />

drive or as a spare drive (usually indicated as a "New Drive"), and<br />

then press [ENTER]. Choose “Add Global Spare Drive.” When<br />

prompted to “Add Global Spare Drive?,” choose Yes.<br />

8.9 Viewing and Editing Logical Drive and<br />

Drive Members<br />

Choose “View and Edit Logical Drives” in the main menu. The<br />

current logical drive configuration and status will be displayed on the<br />

screen. Refer to the previous chapter for more details on the legends<br />

used in Logical Drive’s Status. To view the SCSI drive members of the<br />

logical drive, choose the logical drive by pressing [ENTER].<br />

Choose “View SCSI Drives.” The member drive information will be<br />

displayed on the screen.<br />

Deleting Logical Drive<br />

Choose the logical drive you wish to delete, then press [ENTER].<br />

Choose “Delete logical drive.” Choose Yes when prompted to<br />

confirm.<br />