12-16<br />

12.3 Configuration<br />

Listed below are steps necessary for configuring a redundant<br />

controller system:<br />

1. Configure, separately, each controller in "Autoconfig" mode.<br />

When two controllers are powered on later, firmware will<br />

determine which is the Primary.<br />

2. If SCSI channel 0 is used as the communications channel,<br />

firmware will display channel status as "RCCOM (Redundant<br />

<strong>Controller</strong> Communications)." This channel will then be excluded<br />

from the use of host/drive connection.<br />

3. When powering on both controllers together, LCD will display<br />

"RC connecting." After the controller negotiation is completed, the<br />

communications between controllers will be established.<br />

4. Configure your SCSI/Fibre channels as host or drive. The default<br />

configuration for SCSI channel termination is "enabled." Please<br />

refer to Appendix D of your controller Hardware <strong>Manual</strong> and<br />

examine whether the termination jumpers on controller backplane<br />

are shunted. If the associated jumpers are shunted, SCSI channels<br />

will be terminated on the controller side no matter firmware setting<br />

is "enabled" or "disabled."<br />

5. Create a "Primary ID" and a "Secondary ID" on every drive<br />

channel.<br />

6. Reset controller for the configuration to take effect.<br />

7. Create Logical drives/logical volumes and assign each logical<br />

unit to the Primary or to the Secondary controller.<br />

8. Proceed with Host LUN mapping. After mapping each logical<br />

unit to a Primary or Secondary ID on host channel(s), the<br />

redundant controller configuration is complete.<br />

12.3.1 Via Front Panel Keypad<br />

Redundant Configuration Using Automatic Setting<br />

Power-on <strong>Controller</strong> 1. Make sure <strong>Controller</strong> 2 is powered-off.<br />

<strong>Infortrend</strong>