08.11.2012 Views

Infortrend RAID Controller Manual

Infortrend RAID Controller Manual

Infortrend RAID Controller Manual

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Data Safety:<br />

Redundant <strong>Controller</strong><br />

firmware<br />

synchronization<br />

Regenerate Parity of<br />

logical drives<br />

In the event of controller failure, a replacement controller<br />

running a different version of firmware can be combined to<br />

restore a redundant system with a failed controller.<br />

Different firmware versions can be auto-synchronized<br />

later.<br />

Supported. Can be performed every so often by user to<br />

ensure that bad sectors do not cause data loss in the<br />

event of drive failure.<br />

Supported. Automatic reassignment of bad block<br />

Bad block autoreassignment<br />

Battery backup for Supported. The battery backup solutions provide long-<br />

cache memory<br />

lasting battery support to the cache memory when power<br />

failure occurs. The unwritten data in the cache memory<br />

can be committed to drive media when power is restored.<br />

Verification on Normal Supported. Performs read-after-write during normal write<br />

Writes<br />

processes to ensure data is properly written to drives.<br />

Verification on Rebuild Supported. Performs read-after-write during rebuild write<br />

Writes<br />

to ensure data is properly written to drives.<br />

Verification on LD Supported. Performs read-after-write during logical drive<br />

initialization writes initialization to ensure data is properly written to drives.<br />

Drive S.M.A.R.T. Supported. Drive failure is predictable with reference to<br />

support<br />

the variables detected. Reaction schemes are selectable<br />

from Detect only, Perpetual Clone and Copy + Replace.<br />

These options help to improve MTBF.<br />

Clone Failing Drive Users may choose to clone data from a failing drive to a<br />

backup drive manually<br />

System Security:<br />

Password protection Supported. All settings requires the correct password (if<br />

set) to ensure system security.<br />

User-configurable Supported. After certain time in absence of user<br />

Password validation interaction, the password will be requested again. This<br />

timeout<br />

helps to avoid unauthorized operation when user is away.<br />

Firmware Functionality Specifications B-7