2-Line LCD Hot CPU (_.__ C) Temp Warning<br />

Terminal [0123] Peripheral Device ALERT: CPU Hot Temperature Detected<br />

(current_temperature)<br />

Event Type �Critical �Warning �Notification<br />

What Abnormally high CPU temperature detected, temperature is higher<br />

Happens? than the preset threshold.<br />

What to<br />

Do?<br />

Check the CPU temperature threshold and contact the service<br />

department your <strong>RAID</strong> system supplier.<br />

2-Line LCD Cold CPU (_.__ C) Temp Warning<br />

Terminal [0123] Peripheral Device ALERT: CPU Cold Temperature Detected<br />

(current_temperature)<br />

Event Type �Critical �Warning �Notification<br />

What Abnormally low CPU temperature detected, temperature is lower than<br />

Happens? the preset threshold.<br />

What to<br />

Do?<br />

Check the CPU temperature threshold and contact the service<br />

department your <strong>RAID</strong> system supplier.<br />

2-Line LCD Hot Board (_.__ C) Temp Warning<br />

Terminal [0123] Peripheral Device ALERT: Board Hot Temperature Detected<br />

(current_temperature)<br />

Event Type �Critical �Warning �Notification<br />

What Abnormally high board temperature detected, temperature is higher<br />

Happens? than the preset threshold.<br />

What to<br />

Do?<br />

Check the board temperature threshold and contact the service<br />

department your <strong>RAID</strong> system supplier.<br />

2-Line LCD Cold Board (_.__ C) Temp Warning<br />

Terminal [0123] Peripheral Device ALERT: Board Cold Temperature Detected<br />

(current_temperature)<br />

Event Type �Critical �Warning �Notification<br />

What Abnormally low board temperature detected, temperature is lower<br />

Happens? than the preset threshold.<br />

What to<br />

Do?<br />

Check the board temperature threshold and contact the service<br />

department your <strong>RAID</strong> system supplier.<br />

2-Line LCD UPS Power Failure Detected<br />

Terminal [0124] Peripheral Device ALERT: UPS Power Failure Detected<br />

Event Type �Critical �Warning �Notification<br />

What<br />

Happens?<br />

UPS AC power failure detected on fault-bus.<br />

What to<br />

Do?<br />

Check AC power status or connection cable between UPS and <strong>RAID</strong><br />

system.<br />

Event Messages D-5