2-Line LCD High +12V Voltage Detected (_.__)<br />

Terminal [3F21] ALERT: +12V High Voltage Detected (current_voltage)<br />

Event Type �Critical �Warning �Notification<br />

What The current +12V voltage source is now higher than the preset voltage<br />

Happens? threshold.<br />

D-20<br />

What to<br />

Do?<br />

Check the power supply, voltage threshold settings and contact the<br />

service department of your <strong>RAID</strong> system supplier.<br />

2-Line LCD Low +12V Voltage Detected (_.__)<br />

Terminal [3F21] ALERT: +12V Low Voltage Detected (current_voltage)<br />

Event Type �Critical �Warning �Notification<br />

What The current +12V voltage source is now lower than the preset voltage<br />

Happens? threshold.<br />

What to<br />

Do?<br />

Check the power supply, voltage threshold settings and contact the<br />

service department of your <strong>RAID</strong> system supplier.<br />

2-Line LCD SAF-TE_: Fan(_) Failure Detected<br />

Terminal [3F22] SAF-TE Device (_) ALERT: Cooling Fan Failure Detected (_)<br />

Event Type �Critical �Warning �Notification<br />

What<br />

Happens?<br />

Cooling fan failure detected by SAF-TE enclosure management.<br />

What to<br />

Do?<br />

Check cooling fan(s) of the <strong>RAID</strong> enclosure, and contact the service<br />

department of your <strong>RAID</strong> system supplier.<br />

2-Line LCD SAF-TE_: Elevated Temperature Alert<br />

Terminal [3F23] SAF-TE Device (_) ALERT: Elevated Temperature Alert<br />

Event Type �Critical �Warning �Notification<br />

What<br />

Happens?<br />

Abnormally high temperature detected by SAF-TE facility.<br />

What to<br />

Do?<br />

Contact the service department your <strong>RAID</strong> system supplier.<br />

2-Line LCD SAF-TE_: Power(_) Back To On-Line<br />

Terminal [3FA1] SAF-TE Device (_) NOTICE: Power Back On-Line (_)<br />

Event Type �Critical �Warning �Notification<br />

What<br />

Happens?<br />

Power supply back to on-line state.<br />

What to<br />

Do?<br />

Press to clear the message.<br />