Figure 12 - 10 <strong>Controller</strong> Failover<br />

E. <strong>Controller</strong> Failure<br />

<strong>Controller</strong> failure is managed by the existing controller. The<br />

existing controller disables and disconnects from its counterpart<br />

while gaining access to all the signal paths. The existing<br />

controller then manages the ensuing event notifications and takeover<br />

process. The existing controller is always the Primary<br />

controller regardless of its original status and any replacement<br />

recombined afterwards will assume the role of the Secondary.<br />

Symptoms<br />

� LCD on the failed controller is off. LCD on the existing controller<br />

displays controller failure message.<br />

� The existing controller sounds alarm<br />

� The "ATTEN" LED flashing on the existing controller<br />

� The existing controller sends event messages notifying controller<br />

failure<br />

Redundant <strong>Controller</strong> 12-9