08.11.2012 Views

Infortrend RAID Controller Manual

Infortrend RAID Controller Manual

Infortrend RAID Controller Manual

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Power off controller 2.<br />

Starting the Redundant <strong>Controller</strong>s<br />

Power on all hard drives and the two<br />

controllers. The message "RC (redundant<br />

controller) connecting... to cancel"<br />

will appear on the LCD display of the two<br />

controllers. After a few seconds, the<br />

Primary controller will startup with the<br />

model number and firmware version<br />

displayed on the LCD, while the<br />

Secondary controller will display the<br />

message "RC Standing By.. to<br />

Cancel" on its LCD. A few seconds later,<br />

the LCD display on the Secondary<br />

controller will be similar to the LCD<br />

display on the Primary controller. The<br />

upper right corner of LCD will then be<br />

displaying a “P” or ”S,” meaning<br />

“Primary” or “Secondary” respectively.<br />

During normal operation, the controllers continuously monitor each<br />

other. Each controller is always ready to take over for the other<br />

controller in an unlikely event of a controller failure.<br />

The Primary and Secondary controllers synchronize each other’s<br />

configurations at frequent intervals through the communications<br />

channel(s). Write-back caching will be disabled on the 3102 series if<br />

the connection between controllers is made by a redundant controller<br />

cable without using channel 0 as the synchronized cache channel.<br />

Creating Primary and Secondary ID<br />

Enter "View and Edit SCSI Channels."<br />

Press [ENT] and use ▼ or ▲ to select the<br />

host or drive channel on which you wish<br />

to create Primary/Secondary ID.<br />

Press [ENT] to proceed.<br />

Use ▼ or ▲ to select "Set SCSI Channel<br />

Pri. Ctlr ID .." or " "Set SCSI Channel Sec.<br />

Ctlr ID …" Press [ENT] to proceed.<br />

Use ▼ or ▲ to select a SCSI ID and press<br />

[ENT] to confirm. The configuration<br />

change will take effect only after controller<br />

reset.<br />

RC connecting...<br />

to cancel<br />

View and Edit<br />

SCSI Channels ↕<br />

...<br />

CH1=Drive PID=7<br />

SID=NA SXF=40.0M<br />

Set SCSI Channel<br />

Sec. Ctlr ID ..<br />

Set Sec. Ctlr<br />

ID:NA to ID: 6?<br />

Redundant <strong>Controller</strong> 12-19

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!