8.12 Viewing and Editing SCSI Channels<br />

Except for those shipped in dual-redundant chassis, the factory<br />

default uses channel 0 as the host channel and also the<br />

communications path between controllers. If redundant controller<br />

configuration is preferred, you may need to assign other channel(s) as<br />

host. Flexibility is added for all channels can be configured as host or<br />

drive.<br />

Choose “View and Edit SCSI Channels” in the main menu. Channel<br />

status will be displayed on the screen.<br />

Redefining Channel Mode<br />

All channels can be changed into host mode or drive mode. Choose<br />

the channel you wish to change, then press [ENTER]. Choose<br />

“Channel Mode,” then press [ENTER]. A dialog box will appear<br />

asking you to confirm the change.<br />

Channel mode is related to the topological scheme. You may consider<br />

using data paths in pairs with host software support so that data<br />

access will not be interrupted if one data path should fail. More<br />

information on topologies is provided in the Hardware <strong>Manual</strong>s that<br />

came with your controller.<br />

IMPORTANT!<br />

• Every time you change the channel mode, you must reset the controller for the change<br />

to take effect.<br />

Terminal Operation 8-21