Logical Drive Event:<br />

2-Line LCD CHL=_ ID=_ Drive Failure<br />

Terminal [2101] LG:_ Logical Drive ALERT: CHL:_ ID:_ SCSI Drive Failure<br />

Event Type �Critical �Warning �Notification<br />

What<br />

Happens?<br />

The specified hard drive in the specified logical drive has failed.<br />

What to<br />

Do?<br />

Bringing a new drive or spare drive to rebuild.<br />

2-Line LCD LG ALERT: Init Failed!<br />

Terminal [2102] LG:_ Logical Drive ALERT: Initialization Failed<br />

Event Type �Critical �Warning �Notification<br />

What<br />

Happens?<br />

What to<br />

Do?<br />

Logical drive initialization failed. It could be one of the following<br />

reason:<br />

1. Logical drive initialization canceled by user.<br />

2. On of the member drives failed during logical drive initialization.<br />

3. One of the member drive encountered bad block.<br />

Replace the failed drive and perform logical drive initialization again.<br />

2-Line LCD LG=_ Rebuild Failed<br />

Terminal [2103] LG:_ Logical Drive ALERT: Rebuild Failed<br />

Event Type �Critical �Warning �Notification<br />

What<br />

Happens?<br />

What to<br />

Do?<br />

Logical drive rebuild failed. It could be one of the following reason:<br />

1. The rebuild has been canceled by user.<br />

2. The drive using for rebuild might failed during rebuild.<br />

3. Other member drives encountered bad block during the rebuild.<br />

Using another new drive to perform the rebuild again.<br />

2-Line LCD LG=_ Check Parity Failed !<br />

Terminal [2104] LG_ Logical Drive ALERT: Parity Check Failed<br />

Event Type �Critical �Warning �Notification<br />

What<br />

Happens?<br />

One member drive of the logical drive has failed.<br />

What to<br />

Do?<br />

Rebuild the logical drive first, then perform check parity. Check parity<br />

can only be performed on a logical drive with “Good” (GD) status.<br />