Figure 2 - 7 <strong>RAID</strong> 3<br />

Logical Drive Physical Disks<br />

Block 1<br />

Block 2<br />

Block 3<br />

Block 4<br />

Block 5<br />

Block 6<br />

Block 7<br />

Block 8<br />

.<br />

.<br />

Block 1<br />

Block 3<br />

Block 5<br />

Block 7<br />

.<br />

.<br />

Figure 2 - 8 <strong>RAID</strong> 5<br />

Block 1<br />

Block 2<br />

Block 3<br />

Block 4<br />

Block 5<br />

Block 6<br />

Block 7<br />

Block 8<br />

.<br />

.<br />

<strong>RAID</strong> 3<br />

Disk Striping with Dedicated Parity Disk<br />

Striping<br />

<strong>RAID</strong> 5<br />

Block 2<br />

Block 4<br />

Block 6<br />

Block 8<br />

Logical Drive Physical Disks<br />

Block 1<br />

Parity (3,4)<br />

Block 6<br />

Block 7<br />

.<br />

.<br />

.<br />

.<br />

Block 2<br />

Block 3<br />

Parity (5,6)<br />

Block 8<br />

.<br />

.<br />

Dedicated<br />

Parity<br />

Parity (1,2)<br />

Parity (3,4)<br />

Parity (5,6)<br />

Parity (7,8)<br />

Striping with Interspersed Parity<br />

.<br />

.<br />

Striping + non-dedicated Parity<br />

Parity (1,2)<br />

Block 4<br />

Block 5<br />

Parity (7,8)<br />

.<br />

.<br />

<strong>RAID</strong> 3<br />

Minimum Disks 3<br />

required<br />

Capacity N-1<br />

Redundancy Yes<br />

<strong>RAID</strong> 3 performs Block Striping with<br />

Dedicated Parity. One drive member is<br />

dedicated to storing the parity data. When a<br />

drive member fails, the controller can<br />

recover/regenerate the lost data of the failed<br />

drive from the dedicated parity drive.<br />

<strong>RAID</strong> 5<br />

Minimum Disks 3<br />

required<br />

Capacity N-1<br />

Redundancy Yes<br />

<strong>RAID</strong> 5 is similar to <strong>RAID</strong> 3 but the<br />

parity data is not stored in one<br />

dedicated hard drive. Parity information<br />

is interspersed across the drive array. In<br />

the event of a failure, the controller can<br />

recover/regenerate the lost data of the<br />

failed drive from the other surviving<br />

drives.<br />