9-14<br />

With firmware release 3.14 and above, redundant controllers can<br />

communicate through Fibre channels. At this stage of development,<br />

this feature is supported with the Eon<strong>RAID</strong> series (6-channel). If RCC<br />

(Redundant <strong>Controller</strong> Communications) over Fibre is preferred, some<br />

failover signals must be connected externally using the supplied 4pin<br />

RCC cables.<br />

Two schemes are available for controller communications over Fibre<br />

loops. Hardware configuration should be completed before firmware<br />

setting.<br />

1. Dedicated Communications loops: One or two Fibre<br />

channels (designated as host channel) can be converted into<br />

the dedicated communications path for synchronizing cache<br />

and configuration data. Select from the main menu "View<br />

and Edit SCSI channels," and configure the selected FC<br />

channels into "RCCOM (Redundant <strong>Controller</strong><br />

Communication)" mode. To guarantee data path<br />

redundancy, you may use two channels as the dedicated<br />

RCC loops. The dedicated channels should not be attached<br />

with any other devices.<br />

2. Communications traffic distributed over all drive loops:<br />

Select all drive loops and configure them as "Drive+RCCOM<br />

(Drive Loops and Redundant <strong>Controller</strong> Communications)."<br />

The communications traffic between the two controllers will<br />

be automatically distributed over all drive loops.<br />

1. As displayed above, channel(s) selected as the<br />

communications paths will be displayed as<br />

"channel number (C: connected)" or "channel<br />

number (D: disconnected)." If channels configured<br />

in a dual-loop are selected, channel status will be<br />

displayed as "channel number (pair loop; C or D)."<br />

2. If any communications loop should fail, the intercontroller<br />

traffic will be automatically shifted to over<br />

the remaining RCC loop(s).<br />

Here is an example of Fibre-Fibre RCC configuration:<br />

<strong>Controller</strong><br />

Daughterboard Expansion<br />

<strong>Controller</strong> Presence Detect<br />

Eon<strong>RAID</strong> 2000-6 x 2<br />

2 channels with 9282FA<br />

Signals connected through 4-pin RCC cables<br />

<strong>Infortrend</strong>