B-6<br />

Automatic Failover Yes for all PowerPC controllers (user's interaction<br />

necessary)<br />

Automatic Failback Yes for all PowerPC controllers (user's interaction<br />

necessary)<br />

Fibre channel redundant Supported.<br />

controller<br />

<strong>Controller</strong> Hot-Swap � No need to shut down the failed controller before<br />

replacing the failed controller. (Customer's design-in<br />

hot-swap mechanism necessary)<br />

� Support on-line hot-swap of the failed controller.<br />

There is no need to reset or shutdown the failed<br />

controller. One controller can be pulled out during<br />

active I/Os to simulate the destructive controller failure.<br />

(Customer's design-in hot-swap mechanism<br />

necessary)<br />

Redundant <strong>Controller</strong> Sentinel<strong>RAID</strong>: SCSI; RCC Reset signals built-in<br />

Communication channel Eon<strong>RAID</strong>: Fibre channel(s); RCC cable necessary<br />

Redundant <strong>Controller</strong><br />

Communication over Dedicated loops or distribution over drive loops selectable<br />

Fibre loops<br />

No Single-point-of- Supported.<br />

failure<br />

Automatic engagement Supported in PowerPC series<br />

of replacement<br />

controller<br />

Dynamic cache memory Yes. Cache memory is dynamically allocated, not fixed.<br />

allocation<br />

Environment<br />

Supported. SAF-TE, S.E.S., ISEMS (I<br />

management<br />

2C interface); and<br />

on-board controller voltage/temp monitor are all supported<br />

in both single and redundant controller mode. In the event<br />

of controller failure, serves can be taken over by the<br />

existing controller.<br />

Cache battery backup Supported. Battery backup solutions for cache memory<br />

are supported in both single controller and redundant<br />

modes.<br />

Load sharing Supported. Workload can be flexibly divided between<br />

different controllers by assigning logical configurations of<br />

User configurable<br />

channel mode<br />

Require a special<br />

Firmware for redundant<br />

controller?<br />

Redundant <strong>Controller</strong><br />

rolling firmware upgrade<br />

drives (LDs/LVs) to different controllers.<br />

Supported. Channel modes configurable (SCSI or Fibre)<br />

as HOST or DRIVE in both single controller and redundant<br />

controller mode.<br />

No. All firmware and all <strong>Infortrend</strong> external <strong>RAID</strong><br />

controllers support redundant controller function.<br />

Firmware upgrade can be downloaded to the primary<br />

controller and then be adopted by both controllers, without<br />

interrupting host I/O.<br />

<strong>Infortrend</strong>