8-38<br />

SCSI Drive Read/Write Test<br />

From the “View and Edit SCSI Drives” menu, select a new or used<br />

drive that the utility is to perform on; then press [ENTER]. Select<br />

“SCSI Drive Utilities," then press [ENTER]. Choose “Read/Write<br />

Test” and press [ENTER]. You can choose to enable/disable the<br />

following options:<br />

1. Auto Reassign Bad Block;<br />

2. Abort When Error Occurs;<br />

3. Drive Test for - Read Only/Read and Write.<br />

When finished with configuration, select "Execute Drive Testing" and<br />

press [ENTER] to proceed.<br />

The Read/Write test progress will be indicated by a status bar.<br />

You may press [ESC] and select "Read/Write Test" later and choose<br />

either to "View Read/Write Testing Progress" or to "List Current Bad<br />

Block Table." If you want to stop testing the drive, select "Abort Drive<br />

Testing" and press [ENTER] to proceed.<br />