08.11.2012 Views

Infortrend RAID Controller Manual

Infortrend RAID Controller Manual

Infortrend RAID Controller Manual

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

following chapters. The configuration process will be demonstrated<br />

in LCD mode and terminal mode.<br />

1. Start terminal emulation (please refer to Chapter 4, your enclosure<br />

manual and the controller Hardware <strong>Manual</strong> that came with your<br />

controller). You may also begin with the LCD keypad or<br />

<strong>RAID</strong>Watch manager.<br />

2. Fine-tune the controller optimization parameters for your host<br />

applications. Although the factory defaults guarantee the<br />

optimized controller operation, you may refer to the table below to<br />

facilitate tuning of your array. Some of the performance and faulttolerance<br />

settings may also be changed later during the<br />

preparation process of your disk array.<br />

Table 3 - 2 <strong>Controller</strong> Parameter Settings<br />

�� Parameters that should be configured at the initial stage of<br />

system configuration<br />

�� Parameters that can be changed later<br />

�� non-critical<br />

User-Defined<br />

Parameter<br />

Fault Management:<br />

�� Automatic Logical<br />

Drive Rebuild - Spare<br />

Drive<br />

Default Alternate Settings<br />

Enabled when<br />

Spare Drive is<br />

available<br />

<strong>RAID</strong> 1 + Local Spare<br />

<strong>RAID</strong> 3 + Local Spare<br />

<strong>RAID</strong> 5 + Local Spare<br />

Global Spare<br />

�� S.M.A.R.T. Disabled Detect Only<br />

Perpetual Clone<br />

Clone + Replace<br />

�� Clone Failing Drive <strong>Manual</strong><br />

Replace After Clone<br />

�� Rebuild Priority<br />

function<br />

Low (higher<br />

Perpetual Clone<br />

Low<br />

priority requires Normal<br />

more system Improved<br />

�� Verification on Write<br />

resource)<br />

Disabled<br />

High<br />

On LD Initialization<br />

On LD Rebuild<br />

On Normal Drive Writes<br />

�� SDRAM ECC<br />

�� Event Notification<br />

Disabled<br />

Reports to user<br />

Enabled<br />

Over Dial-out Modem<br />

interface and Over SNMP Trap<br />

onboard alarm Over Java-Based Management<br />

Software<br />

�� System Events System default Upper and Lower event<br />

triggering thresholds configurable<br />

Optimization Mode:<br />

�� Write-back Cache Enabled Disabled<br />

�� Optimization for Sequential Either (default and must be<br />

<strong>RAID</strong> Planning 3-7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!