8-26<br />

IMPORTANT!<br />

• Every time you change the SCSI Transfer Width, you must reset the controller for the<br />

changes to take effect.<br />

Viewing and Editing SCSI Target / Drive Channel<br />

NOTE:<br />

Move the cursor bar to a Drive channel, then press [ENTER]. Select<br />

“View and Edit SCSI Target,” then press [ENTER].<br />

A list of all the SCSI targets and their current settings will appear.<br />

Press [ENTER] on a SCSI target and a menu list will appear on the<br />

screen.<br />

• It is only recommended to alter the SCSI target settings when adjustments should be<br />

made to specific devices on a drive channel. You may change the SCSI parameters for<br />

specific drives when mixing different drives or connecting other SCSI device like a<br />

CD-ROM on a drive channel. Please note that neither mixing drives nor connecting<br />

CD-ROM is recommended for the controller.<br />

Slot Number<br />

Choose “Slot Number”, then press [ENTER]. Enter a slot number,<br />

then press [ENTER] again.<br />

Please refer to Chapter 14, "Fault-Bus," for more information.<br />