8-22<br />

Viewing and Editing SCSI IDs / Host Channel<br />

Choose a host channel, then press [ENTER]. Choose “View and Edit<br />

SCSI ID.” A list of existing ID(s) will be displayed on the screen.<br />

Viewing and Editing SCSI IDs / Drive Channel<br />

Adding a SCSI ID (Primary/Secondary <strong>Controller</strong> ID)<br />

Press [ENTER] on one of the existing SCSI IDs. Choose “Add<br />

Channel SCSI ID,” then choose to assign an ID for either the “Primary<br />

<strong>Controller</strong>” or "Secondary <strong>Controller</strong>." A list of SCSI IDs will appear.<br />

Choose a SCSI ID. DO NOT choose a SCSI ID used by another device<br />

on the same channel. The defaults are PID=0 and SID=1 (SCSI<br />

channel). In redundant mode, logical drives mapped to a primary ID<br />

will be managed by the primary controller, and vice versa.<br />

Host channel supports multiple IDs. One exception to this is Fibre<br />

channel. For controllers running firmware 3.21, each Fibre channel<br />

processor supports two hardware address IDs. For controllers<br />

running former firmware versions, two host channels are required for<br />

active-to-active configuration. Avail either a primary or a secondary<br />

ID on each of the host channels.<br />