12-10<br />

F. Considerations with Redundant <strong>Controller</strong>s<br />

� SCSI Termination:<br />

For the Sentinel<strong>RAID</strong> series in redundant mode, the on-board<br />

terminators should be hardware-enabled by jumper switches.<br />

Integrators may apply external terminators at both ends of a<br />

SCSI bus or choose to enable the on-board terminators on the<br />

controller I/O backplane. The precaution is that, terminators<br />

must be "hardware-enabled" via jumper switches rather than<br />

"firmware-enabled." Although terminators can be activated via<br />

firmware settings, firmware control is lost when a controller<br />

fails. Settings via firmware will result in SCSI bus failure<br />

because every channel is connected between controllers.<br />

For the 3101 and 3102 series, external terminators should be<br />

applied instead. Please refer to the Hardware <strong>Manual</strong> for details.<br />

� Connection:<br />

The channels of the two controllers that are connected together<br />

must be the same. For example, if controller 1 uses channel 2 to<br />

connect a group of drives, controller 2 must also use channel 2<br />

to connect to the drive group.<br />

<strong>Infortrend</strong>