Examining Whether Your Drives Support S.M.A.R.T.<br />

To see if your drive supports S.M.A.R.T., follow the steps below:<br />

3. Enable “S.M.A.R.T.” on the <strong>RAID</strong> controller.<br />

4. In “View and Edit SCSI Drives,” choose one drive to test to. Press<br />

[ENTER] on the drive, a sub-menu will appear.<br />

5. Notice that a new item “Predictable Failure Test” appears in the<br />

sub-menu. If the SMART” feature is not enabled properly, this item<br />

will not appear in this sub-menu.<br />

6. Choose “Predictable Failure Test,” the controller will force the<br />

drive to simulate the predictable drive error.<br />

7. Press [ENTER], and after a while (the next time the controller<br />

performs “Periodic Drive Check”), the controller will detect the error<br />

simulated by the drive. An error message will be displayed: “[1142]<br />

SMART-CH:? ID:? Predictable Failure Detected (TEST).” If this error<br />

message appears, it means the selected drive supports S.M.A.R.T.<br />

feature. If this error message does not appear, it means that this drive<br />

does not support S.M.A.R.T..<br />

8. Otherwise, you may simply contact the drive manufacturer for<br />

information about whether the drive model and drive firmware<br />

revision support S.M.A.R.T. feature.<br />