10.4 Disk Array Parameters<br />

Select “View and edit Configuration parameters” on the main menu<br />

and press [ENTER]. Choose “Disk Array Parameters,” then press<br />

[ENTER] again. The Disk Array Parameters menu will appear.<br />

Rebuild Priority<br />

Choose “Rebuild Priority,” then press [ENTER]. A list of the priority<br />

selections (Low, Normal, Improved, or High) will appear. Move the<br />

cursor bar to a selection, then press [ENTER].<br />

Verification on Writes<br />

Normally, errors may occur when a hard drive writes data. In order<br />

to avoid the write error, the controller can force the hard drives to<br />

verify the written data. There are three selectable methods:<br />

� Verification on LD Initialization Writes<br />

Performs Verify-after-Write while initializing the logical<br />

drive.<br />

� Verification on LD Rebuild Writes<br />

Performs Verify-after-Write during the rebuilding process.<br />

� Verification on LD Normal Drive Writes<br />

Performs Verify-after-Write during normal I/O requests.<br />

Each method can be enabled or disabled individually. Hard drives<br />

will perform Verify-after-Write according to the selected method.<br />

Advanced Configurations 10-37