9-6<br />

Figure 9 - 1 Host Loop Connection: Eon<strong>RAID</strong> 2000-4 in<br />

Redundant Mode<br />

<strong>Controller</strong>/Host Channel Status ID Mapping<br />

A/ Fibre channel 0 Active Primary ID<br />

A/ Fibre channel 1 Standby N/A<br />

B/ Fibre channel 0 Standby N/A<br />

B/ Fibre channel 1 Active Secondary ID<br />

In the unlikely event of controller failure, the standby channels on an<br />

existing controller becomes an active route serving the host I/Os<br />

originally directed to the active channel on its pair controller. In<br />

addition to this, "application failover" software should be running on<br />

host computer to control the transfer of I/Os from one HBA to another<br />

should either of the data paths fail.<br />

Table 9 - 1 Supported Configurations with Redundant<br />

<strong>Controller</strong>:<br />

<strong>Controller</strong> Host/Drive<br />

Connection<br />

Host Side Cabling<br />

Topology<br />

Sentinel<strong>RAID</strong> series Fibre to SCSI Hub (private or public<br />

loop)/direct host-storage<br />

Sentinel<strong>RAID</strong> R3 series Fibre to SCSI Hub/point-to-point/<br />

Fabric<br />

Eon<strong>RAID</strong> 2000-4 & Fibre to Fibre Hub (private or public<br />

2000-6<br />

loop)/direct host-storage<br />

Eon<strong>RAID</strong> 2000 R1 &<br />

2000R2<br />

Fibre to Fibre Hub/point-to-point/<br />

Fabric<br />

<strong>Controller</strong> Drive Side cabling<br />

Topology<br />

Sync. Cache Connection<br />

Sentinel<strong>RAID</strong> series SCSI SCSI CH0<br />

Sentinel<strong>RAID</strong> R3<br />

series<br />

SCSI SCSI CH0<br />

Eon<strong>RAID</strong> 2000-4 & Drive Dual Loop SCSI CH6/7, dedicated<br />

2000-6<br />

supported<br />

loops, or all drive loops<br />

Eon<strong>RAID</strong> 2000 R1 &<br />

2000R2<br />

Drive Dual Loop<br />

supported<br />

SCSI CH6/7, dedicated<br />

loops, or all drive loops<br />

<strong>Infortrend</strong>