7-6<br />

7.7 SCSI Channel’s Status<br />

Chl<br />

Mode<br />

PID<br />

SID<br />

SCSI channel’s ID.<br />

Channel mode.<br />

RCCom Redundant controller communication channel<br />

Host Host Channel mode<br />

Drive Drive Channel mode<br />

Primary controller’s SCSI ID mapping:<br />

* Multiple SCSI IDs were applied (Host Channel mode<br />

only).<br />

(ID<br />

number)<br />

The Primary <strong>Controller</strong> is using the SCSI ID for host<br />

LUN mapping.<br />

NA No SCSI ID applied (Drive Channel mode only).<br />

Secondary controller’s SCSI ID mapping:<br />

* Multiple SCSI IDs were applied (Host Channel mode<br />

only).<br />

(ID<br />

number)<br />

The Primary <strong>Controller</strong> is using the SCSI ID for host<br />

LUN mapping.<br />

NA No SCSI ID applied<br />

DefSynClk Default SCSI bus synchronous clock:<br />

DefWid<br />

S<br />

Term<br />

??.?M<br />

The default setting of the SCSI channel is 20.0 MHz<br />

in Synchronous mode.<br />

Async. The default setting of the SCSI channel is<br />

Asynchronous mode.<br />

Default SCSI Bus Width:<br />

Wide 16-bit SCSI<br />

Narrow 8-bit SCSI<br />

Signal:<br />

S Single-ended<br />

L LVD<br />

F Fibre<br />

Terminator Status:<br />